SyncAI.news, a Varaisys broadcasting
Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening
BR

Benjamin Renoust, Pierre Baudot, Tiffany Foriel, Yousra Haddou, Charles Voyton, Pierre-Henri Siot, Ezequiel Geremia, Danny Francis, Jean-Christophe Brisset, Val\'erie Bourd\`es, Sylvain Bodard, Benoit Huet

· 1 min read

ResearcharXiv cs.CV

Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening

arXiv:2609.22281v1 Announce Type: new Abstract: Foundation models have recently demonstrated strong capabilities across a wide range of medical imaging tasks. However, their performance in structured clinical interpretation settings remains insufficiently explored. In lung cancer screening, interpretative variability persists despite standardized frameworks such as Lung-RADS. In this study, we evaluate MedGemma, a medical general-purpose foundation model derived from Gemini and its fine-tuned version adapted for lung cancer detection and diagnosis, compared against radiologists performing Lung-RADS v2022 assessment on the NLST dataset. Twelve radiologists independently evaluated each case in a multi-reader design, enabling quantification of inter-reader variability. Radiologists achieved a mean AUC of 0.90, with substantial variability across readers (range: 0.80-0.94). The native foundation model achieved an AUC of 0.70, failing to reach clinically relevant performance. In contrast, fine-tuning significantly improved performance to an AUC of 0.83, placing the model within the lower range of individual radiologists performance. These findings highlight a trade-off between peak accuracy and prediction consistency. Unlike radiologists, under fixed conditions, the model produces deterministic outputs, removing inter-run variability under identical inputs, in contrast to inter-reader variability observed among radiologists. This supports the role of fine-tuned foundation models potential complementary tools for clinical decision support, particularly in settings with limited expertise. However, evaluation is performed on a case-enriched cohort from NLST and does not account for real-world prevalence or external validation, limiting direct clinical generalization.

Original source

This story was published by arXiv cs.CV and written by Benjamin Renoust, Pierre Baudot, Tiffany Foriel, Yousra Haddou, Charles Voyton, Pierre-Henri Siot, Ezequiel Geremia, Danny Francis, Jean-Christophe Brisset, Val\'erie Bourd\`es, Sylvain Bodard, Benoit Huet. SyncAI.news shows a preview; the complete article is on the publisher's site.

Read the full story on arxiv.org

Similar News