SyncAI.news, a Varaisys broadcasting
Preoperative Prediction of Microvascular Invasion in Hepatocellular Carcinoma by Integrating Multimodal Ultrasound and Clinical Data: A Multicenter Study
JC

Jun Cheng, Yuanyuan Kong, Qing Huang, Xiaotong Tan, Licong Dong, Yulong Han, Wufeng Xue, Ruobing Huang, Dong Ni, Qi Yang, Jie Yu, Ping Liang

· 1 min read

ResearcharXiv cs.CV

Preoperative Prediction of Microvascular Invasion in Hepatocellular Carcinoma by Integrating Multimodal Ultrasound and Clinical Data: A Multicenter Study

arXiv:2609.24524v1 Announce Type: new Abstract: Background: Microvascular invasion (MVI) predicts recurrence and survival in hepatocellular carcinoma (HCC) but requires postoperative histopathology for diagnosis. We developed and validated a model integrating multimodal ultrasound and clinical data for preoperative MVI prediction. Methods: This multicenter study included 489 patients with HCC from eight centers. All patients had B-mode ultrasound (BUS), color Doppler flow imaging (CDFI), dynamic contrast-enhanced ultrasound (DCE-US), and clinical information. Data from seven centers (n = 421) were used for model development with five-fold cross-validation; data from the remaining center (n = 68) formed an independent external validation cohort. The proposed multimodal information fusion network used modality-specific encoders, a hemodynamic temporal change module for bidirectional DCE-US perfusion changes, and a representation consistency learning module to align heterogeneous ultrasound representations before Transformer-based fusion. Results: In external validation, DCE-US achieved the highest single-modality area under the receiver operating characteristic curve (AUC; 0.8545+/-0.0198), versus clinical information (0.6715+/-0.0156), CDFI (0.6435+/-0.0344), and BUS (0.6087+/-0.0417). Pixel-difference sampling and the proposed temporal module outperformed alternative sampling and video representation methods. The full model achieved the best performance, with an AUC of 0.8953+/-0.0180, accuracy of 81.18%+/-2.83%, sensitivity of 86.40%+/-6.69%, and specificity of 78.14%+/-6.28. Conclusions: Integrating multimodal ultrasound and clinical information enabled promising preoperative MVI prediction in HCC. DCE-US was the main source of predictive information, while BUS, CDFI, and clinical information provided complementary value. The proposed framework may support preoperative risk stratification and individualized clinical decision-making.

Original source

This story was published by arXiv cs.CV and written by Jun Cheng, Yuanyuan Kong, Qing Huang, Xiaotong Tan, Licong Dong, Yulong Han, Wufeng Xue, Ruobing Huang, Dong Ni, Qi Yang, Jie Yu, Ping Liang. SyncAI.news shows a preview; the complete article is on the publisher's site.

Read the full story on arxiv.org

Similar News