SyncAI.news, a Varaisys broadcasting
Vascular anatomy-aware self-supervised pre-training for X-ray angiogram analysis
DH

De-Xing Huang, Chaohui Yu, Xiao-Hu Zhou, Tian-Yu Xiang, Qin-Yi Zhang, Mei-Jiang Gui, Rui-Ze Ma, Chen-Yu Wang, Nu-Fang Xiao, Fan Wang, Zeng-Guang Hou

· 1 min read

ResearcharXiv cs.CV

Vascular anatomy-aware self-supervised pre-training for X-ray angiogram analysis

arXiv:2602.11536v2 Announce Type: replace Abstract: Objective: X-ray angiography is the gold standard imaging modality for cardiovascular diseases. However, current deep learning approaches for X-ray angiogram analysis are severely constrained by the scarcity of annotated data. While large-scale self-supervised learning (SSL) has emerged as a promising solution, its potential in this domain remains largely unexplored, primarily due to the lack of effective SSL frameworks and large-scale datasets. Methods: To bridge this gap, we introduce a vascular anatomy-aware masked image modeling (VasoMIM) framework that explicitly integrates domain-specific anatomical knowledge. Specifically, VasoMIM comprises two key designs: an anatomy-guided masking strategy and an anatomical consistency loss. The former strategically masks vessel-containing patches to compel the model to learn robust vascular semantics, while the latter preserves structural consistency of vessels between the original and reconstructed images, enhancing the discriminability of the learned representations. In conjunction with VasoMIM, we curate XA-170K, the largest X-ray angiogram pre-training dataset to date. Results: We validate VasoMIM on four downstream tasks across six datasets, where it demonstrates superior transferability and achieves state-of-the-art performance compared to existing methods. Conclusion: Incorporating vascular anatomical knowledge into self-supervised pre-training enables more discriminative and transferable representations for X-ray angiogram analysis. Significance: These findings highlight the significant potential of VasoMIM as a foundation model for advancing a wide range of X-ray angiogram analysis tasks. VasoMIM and XA-170K are available on \href{https://github.com/Dxhuang-CASIA/XA-SSL}{GitHub} and \href{https://huggingface.co/datasets/waha2000huang/XA-170K}{Hugging Face}, respectively.

Original source

This story was published by arXiv cs.CV and written by De-Xing Huang, Chaohui Yu, Xiao-Hu Zhou, Tian-Yu Xiang, Qin-Yi Zhang, Mei-Jiang Gui, Rui-Ze Ma, Chen-Yu Wang, Nu-Fang Xiao, Fan Wang, Zeng-Guang Hou. SyncAI.news shows a preview; the complete article is on the publisher's site.

Read the full story on arxiv.org

Similar News